電站(zhàn)測溫用熱電阻
WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量程規格
名稱
|
分度(dù)號
|
測溫範圍℃
|
精度等級(jí)
|
允(yǔn)差Δt
|
鎳鉻-鎳矽(guī)熱電偶
|
K
|
0~800
|
2
|
±2.5℃或 ±0.75%t
|
鎳(niè)鉻-銅鎳熱電偶(ǒu)
|
E
|
0~600
|
2
|
±2.5℃或 ±0.75%t
|
鉑熱電阻
|
Pt100
|
-200~500
|
B
|
±(0.3+0.005|t|)
|
注:t為(wéi)感溫元(yuán)件實測溫(wēn)度或實測(cè)溫(wēn)度的(de)絕對值(zhí)。
□公稱壓力
一般是(shì)指在常溫下,保護管(guǎn)所能承受的靜態(tài)外(wài)壓(yā)而不(bú)破裂,試(shì)驗壓(yā)力一般采用(yòng)公稱壓力的(de)1.5倍。實際上,允許(xǔ)工(gōng)作壓力不僅與(yǔ)保護(hù)管材料、直徑、壁厚有關(guān),而(ér)且還與其結(jié)構(gòu)形式、安裝方法、置入深度(dù)以及被測介質的流速、種類有關。
□熱(rè)電偶(ǒu)絕緣(yuán)電阻
常溫絕緣電阻的試驗電壓為直(zhí)流(liú)500V。測量常溫絕緣電阻的(de)大氣條件為:溫度15~35℃,相(xiàng)對濕度45%RH,大氣壓(yā)力86~106kPa。
對於長度超過1米的熱電偶(ǒu),它的常溫絕(jué)緣電阻(zǔ)值與其長度的乘積應(yīng)不小於100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-熱電偶的常(cháng)溫(wēn)絕緣電(diàn)阻值,MΩ;
L-熱電偶的(de)長度,m。
對於長度等於或不足1米的熱電偶,它的常溫絕緣(yuán)電阻值應不小(xiǎo)於100MΩ。
□熱電阻絕緣電阻
常溫絕緣電阻的試驗電壓可取直流10~100V任意值,環境溫度應在15~35℃範圍內,相對濕度應不(bú)大於(yú)80%RH,常(cháng)溫(wēn)絕緣電阻值(zhí)應不(bú)小於(yú)100MΩ。
□熱電阻允許通過電(diàn)流
通(tōng)過鉑電阻的測量電流(liú)最大不超過5mA。
|