WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量(liàng)程(chéng)規格
名(míng)稱
|
分度號
|
測溫範圍℃
|
精度等級
|
允差Δt
|
鎳鉻-鎳矽熱電偶(ǒu)
|
K
|
0~800
|
2
|
±2.5℃或 ±0.75%t
|
鎳鉻-銅鎳熱電偶
|
E
|
0~600
|
2
|
±2.5℃或 ±0.75%t
|
鉑熱電阻
|
Pt100
|
-200~500
|
B
|
±(0.3+0.005|t|)
|
注(zhù):t為感溫元(yuán)件(jiàn)實(shí)測溫(wēn)度(dù)或實測溫度的絕對值。
□公稱(chēng)壓力
一般是指在常溫下,保護管所能承受(shòu)的(de)靜態外(wài)壓而不破(pò)裂(liè),試驗壓力一般采(cǎi)用(yòng)公稱壓力(lì)的1.5倍。實際上,允(yǔn)許工作壓力不僅與保護管(guǎn)材料、直徑(jìng)、壁(bì)厚有關,而且還與其(qí)結構形(xíng)式、安裝方(fāng)法、置(zhì)入深(shēn)度以及被測(cè)介質的流(liú)速(sù)、種類有關。
□熱電偶絕緣電阻(zǔ)
常溫(wēn)絕緣(yuán)電阻的(de)試(shì)驗電壓為直流500V。測量常溫(wēn)絕緣電阻的大氣條(tiáo)件為(wéi):溫度15~35℃,相(xiàng)對濕度45%RH,大氣壓力86~106kPa。
對(duì)於長度超過1米的熱電偶,它的常(cháng)溫絕(jué)緣電阻值(zhí)與其長度的乘積應不小於100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中(zhōng):Rr-熱電偶的(de)常溫絕緣電阻值,MΩ;
L-熱電偶(ǒu)的(de)長(zhǎng)度,m。
對於長度等於(yú)或不足1米(mǐ)的熱電(diàn)偶,它的常溫(wēn)絕緣電阻值應不小於100MΩ。
□熱電阻絕緣電阻(zǔ)
常(cháng)溫絕緣電阻的(de)試驗電(diàn)壓(yā)可取直(zhí)流10~100V任意值,環境(jìng)溫(wēn)度應在15~35℃範圍(wéi)內,相對濕(shī)度應不大於(yú)80%RH,常溫絕緣電阻值(zhí)應(yīng)不小(xiǎo)於100MΩ。
□熱(rè)電阻(zǔ)允(yǔn)許通過電流
通過鉑(bó)電(diàn)阻的測量電流最大不超過5mA。
|