電站(zhàn)測溫用熱電阻
WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量程規格
名稱(chēng)
|
分度號(hào)
|
測(cè)溫範圍℃
|
精度等級
|
允差Δt
|
鎳鉻-鎳矽熱電偶(ǒu)
|
K
|
0~800
|
2
|
±2.5℃或 ±0.75%t
|
鎳鉻-銅鎳熱電偶
|
E
|
0~600
|
2
|
±2.5℃或 ±0.75%t
|
鉑熱電阻
|
Pt100
|
-200~500
|
B
|
±(0.3+0.005|t|)
|
注:t為感溫元件實測溫度或實(shí)測溫度的絕對(duì)值。
□公稱壓力(lì)
一(yī)般是指在常溫(wēn)下,保護管所(suǒ)能承(chéng)受的(de)靜態外壓而不(bú)破裂,試驗壓力一般采用公稱壓力的1.5倍。實際上(shàng),允許工作壓(yā)力不僅與保護管材料、直徑、壁厚有關(guān),而且還與其結構形式、安裝方法(fǎ)、置入深度以及被測介(jiè)質的流速、種類有(yǒu)關(guān)。
□熱電偶絕緣電阻
常(cháng)溫絕(jué)緣電(diàn)阻的試驗電壓(yā)為直流500V。測(cè)量常溫絕緣電(diàn)阻的大氣條件(jiàn)為:溫(wēn)度15~35℃,相對濕度45%RH,大氣(qì)壓力86~106kPa。
對(duì)於長度超過(guò)1米的熱電偶(ǒu),它的常溫絕緣電阻值與其(qí)長(zhǎng)度的乘積應不小於100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-熱電偶的常溫絕緣(yuán)電阻值,MΩ;
L-熱電偶的長度(dù),m。
對於長度(dù)等(děng)於或不(bú)足(zú)1米的熱(rè)電偶,它的常溫(wēn)絕緣電阻值應不小於100MΩ。
□熱電阻絕(jué)緣(yuán)電阻
常溫絕緣電阻的試驗電壓可取直流10~100V任意值(zhí),環(huán)境溫度應在15~35℃範圍內,相對(duì)濕度應不大(dà)於80%RH,常溫絕緣(yuán)電阻值應不小於100MΩ。
□熱電阻允許通過電流(liú)
通過鉑(bó)電阻的(de)測量電(diàn)流最大不(bú)超過5mA。
|