電站測溫用熱(rè)電阻
WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量程規格(gé)
名稱
|
分度號(hào)
|
測溫範圍℃
|
精度(dù)等級
|
允差Δt
|
鎳鉻(gè)-鎳矽熱電偶
|
K
|
0~800
|
2
|
±2.5℃或 ±0.75%t
|
鎳(niè)鉻-銅鎳熱電偶
|
E
|
0~600
|
2
|
±2.5℃或 ±0.75%t
|
鉑熱電阻
|
Pt100
|
-200~500
|
B
|
±(0.3+0.005|t|)
|
注(zhù):t為感(gǎn)溫元件實測(cè)溫度或實測(cè)溫(wēn)度的絕(jué)對值。
□公稱壓力
一般是指在常(cháng)溫下,保護管所能承受的靜態外壓而不破裂,試驗壓(yā)力(lì)一般采用公稱(chēng)壓力的(de)1.5倍。實際上,允許工作壓力不僅與(yǔ)保護管材料(liào)、直徑、壁厚有(yǒu)關(guān),而且還(hái)與(yǔ)其結構形式、安裝方法、置入(rù)深度以及被(bèi)測介質的流速、種類(lèi)有關(guān)。
□熱(rè)電偶絕緣電阻
常溫絕緣(yuán)電阻的試驗電壓為(wéi)直流500V。測量常溫絕緣(yuán)電(diàn)阻的大氣條件為:溫度15~35℃,相對濕度45%RH,大氣壓(yā)力86~106kPa。
對(duì)於(yú)長度(dù)超過(guò)1米的熱電偶,它的常(cháng)溫絕緣電阻值與(yǔ)其長度(dù)的乘積應不小於100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-熱電偶的常溫絕緣電阻(zǔ)值,MΩ;
L-熱電偶的長度(dù),m。
對於長度(dù)等於或不(bú)足1米的熱電偶,它的常溫絕緣電阻值(zhí)應不小(xiǎo)於100MΩ。
□熱電阻(zǔ)絕緣電阻
常溫絕緣電阻的試驗電壓可取直(zhí)流10~100V任意值,環境溫度應(yīng)在15~35℃範圍內(nèi),相對濕度應不(bú)大於80%RH,常溫絕緣電阻值應(yīng)不小於100MΩ。
□熱電阻允許通過電(diàn)流(liú)
通(tōng)過鉑(bó)電阻的測量(liàng)電流最大不超過5mA。
|