電站測溫用熱(rè)電阻(zǔ)
WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量程規格
名(míng)稱
|
分度號
|
測溫範圍℃
|
精度等級
|
允差(chà)Δt
|
鎳鉻-鎳(niè)矽(guī)熱電偶
|
K
|
0~800
|
2
|
±2.5℃或 ±0.75%t
|
鎳鉻-銅鎳熱電偶
|
E
|
0~600
|
2
|
±2.5℃或 ±0.75%t
|
鉑熱電阻
|
Pt100
|
-200~500
|
B
|
±(0.3+0.005|t|)
|
注:t為感溫元件實測溫度或(huò)實(shí)測(cè)溫度的絕對(duì)值。
□公稱壓(yā)力
一般是指在常溫下,保護(hù)管所能承受的靜態外壓而不破裂(liè),試(shì)驗(yàn)壓力(lì)一(yī)般采用公稱壓(yā)力的1.5倍(bèi)。實際上,允許工作壓力不僅與保(bǎo)護管(guǎn)材料、直徑、壁厚有關,而且還與其結構(gòu)形式、安裝方法、置(zhì)入深度以(yǐ)及(jí)被(bèi)測介質的流速、種類有關。
□熱電偶絕緣電阻
常溫絕緣電(diàn)阻(zǔ)的(de)試驗電壓為直流500V。測量(liàng)常溫(wēn)絕緣電阻的大氣條件(jiàn)為:溫度15~35℃,相對濕度45%RH,大氣(qì)壓力86~106kPa。
對於長度超(chāo)過1米的熱電偶,它的常溫絕緣電阻值與其長度的(de)乘積(jī)應不(bú)小於100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-熱電偶的常溫絕緣電阻值,MΩ;
L-熱電偶的(de)長度(dù),m。
對於長度等於或不(bú)足1米的熱電偶,它的常溫(wēn)絕緣(yuán)電阻(zǔ)值應不(bú)小於100MΩ。
□熱電(diàn)阻(zǔ)絕緣電阻
常(cháng)溫絕緣電阻的試驗(yàn)電壓可取直(zhí)流10~100V任意值,環(huán)境溫(wēn)度應在15~35℃範圍內,相對濕度應不大於(yú)80%RH,常溫(wēn)絕緣電阻值應不小(xiǎo)於100MΩ。
□熱電阻(zǔ)允許通過電(diàn)流
通(tōng)過鉑電阻的測量電流最大不超(chāo)過5mA。
|