電站測溫用(yòng)熱電阻
WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量(liàng)程規格
名稱
|
分度號
|
測溫範圍℃
|
精度等級
|
允差Δt
|
鎳鉻-鎳矽(guī)熱(rè)電(diàn)偶
|
K
|
0~800
|
2
|
±2.5℃或 ±0.75%t
|
鎳鉻-銅鎳(niè)熱電(diàn)偶
|
E
|
0~600
|
2
|
±2.5℃或 ±0.75%t
|
鉑熱電阻
|
Pt100
|
-200~500
|
B
|
±(0.3+0.005|t|)
|
注:t為感溫元件實測溫度或實測溫度的絕對值。
□公稱壓力
一般是指在(zài)常溫下,保護(hù)管所(suǒ)能承受(shòu)的靜態外壓而不破裂(liè),試驗壓力一般(bān)采用公稱壓力的1.5倍(bèi)。實際上(shàng),允(yǔn)許工作壓力不僅(jǐn)與保護管材料(liào)、直徑(jìng)、壁厚有(yǒu)關(guān),而且還與其結構形式、安裝方(fāng)法、置入深度以(yǐ)及被測介質的流(liú)速、種類(lèi)有(yǒu)關。
□熱電偶絕緣電阻
常溫絕(jué)緣電(diàn)阻的試驗電壓為直(zhí)流500V。測量常溫絕緣(yuán)電阻的(de)大(dà)氣條件為(wéi):溫度15~35℃,相對濕度45%RH,大(dà)氣壓(yā)力86~106kPa。
對於長(zhǎng)度超(chāo)過1米的(de)熱電偶,它(tā)的常(cháng)溫(wēn)絕緣電阻值與其(qí)長度的乘積(jī)應不(bú)小(xiǎo)於100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-熱電(diàn)偶的(de)常溫絕緣電阻值,MΩ;
L-熱電偶的(de)長度,m。
對(duì)於長度(dù)等於(yú)或不(bú)足1米的熱電偶,它的常(cháng)溫絕(jué)緣電阻值應不小於100MΩ。
□熱電阻(zǔ)絕緣電(diàn)阻
常溫絕緣電(diàn)阻的試(shì)驗電壓可取直流10~100V任意值,環境溫度應(yīng)在15~35℃範圍內,相對濕度應不大(dà)於80%RH,常溫絕緣(yuán)電阻(zǔ)值應(yīng)不小於100MΩ。
□熱電阻(zǔ)允許通過電流
通過鉑電(diàn)阻的(de)測量電流(liú)最大不超過5mA。
|